Thermal Camera FLIR A65 Radiometric

414.80

FLIR A65 Radiometric thermal imaging camera

Category: Tags: , ,

Description

 

FLIR A65 thermal imaging camera

 

Thermal sensitivity and high image quality

 

Extremely compact: all models are extremely compact. They can be easily integrated into a viewing environment. Choice of image quality: The FLIR A65 produces crisp thermal images of 640 x 512 pixels. Users who do not need this image quality for their application can choose for the A35 FLIR that produces thermal images of 320 x 256 pixels, for the FLIR A15 that produces thermal images of 160 x 128 pixels or for the FLIR A5 that produces thermal images of 80 x 64 pixels.

 

compatible with the GigE Vision ™ standard!

The Flir A65 is compatible with GigE Vision is a new camera interface standard developed using the Gigabit Ethernet communication protocol. GigE Vision is the first industry standard that allows fast image transfer using standard low cost cables over long distances. With GigE Vision, the hardware and software of different suppliers can interact seamlessly on GigE connections. GenICam ™ protocol support: The goal of GenICam is to provide a generic programming interface for all types of cameras. Regardless of the interface technology (GigE Vision, Camera Link, 1394 DCAM, etc.) or implemented features, the Application Programming Interface (API) will always be the same. The GenICam protocol also makes it possible to use third-party software with the camera. GenICam makes the FLIR Axx plug-and-play when used with software packages such as IMAQ Vision and Halcon.

The Flir A65 thermal camera has a 14-bit linear temperature output

 Power over Ethernet (PoE): Communication and power supplied with a single cable. Synchronization: it is possible to configure a camera to be master and to be a slave (s) for applications that require more than one camera to cover the object or for stereoscopic applications.
General Purpose Input / Output (GPIO): An output that can be used to control other equipment and an input to read the state of the equipment .   

Wide temperature range: The FLIR Axx Series displays temperatures between -40 ° C and 550 ° C.     

High sensitivity: thermal sensitivity <50 mK captures the minimum detail information and temperature differences.

FLIR A65 and A35 technical specifications

features
FLIR A65
FLIR A35
Resolution IR 640 × 512 pixel 320 × 256 pixel
Spatial resolution (IFOV) 90 ° × 69 ° with optics from 7,5 mm 63 ° × 50 °with optics from 7,5 mm
45 ° × 37 ° with optics from 13 mm 48 ° × 39 ° with optics from 9 mm
25 ° × 20 ° with optics from 25 mm 24 ° × 19,2 ° with optics from 19 mm
12,4 ° × 9,92 ° with optics from 50 mm 13 ° × 10,8 ° with optics from 35 mm
6,2 ° × 4,96 ° with optics from 100 mm 7,6 ° × 6,08 ° with optics from 60 mm
Image frequency 30 Hz 60 Hz
Sensor specifications
Sensor pitch 17 µm 25 µm
Measurements
Object temperature range from -25 °C a 135 °C/da -40 °C a 550 °C

 

Specifiche termocamera Flir A6

General Specifications Flir A65

Optical data and image

Thermal sensitivity/NETD < 0,05 °C a 30 °C (86 °F) / 50 mK
Accuracy ±5 °C o ±5 % of reading
Number F 1,25
Focus fixed
Focal Plane Array (FPA) / spectral band Microbolometro VOx not cooled/7,5–13 µm
Sensor time constant Typical 12 ms

Ethernet

Ethernet Control and image
Ethernet, tipo Gigabit Ethernet
Ethernet, standard IEEE 802.3/RJ-45
Ethernet, comunicazione GigE Vision ver. Compatibile client API GenICam 1.2
Ethernet, streaming immagini 8-bit monochromatic at 7.5 / 30/60 Hz (depending on the model) Linear / DDE signal, automatic / manual, Reversing O & V14-bit at 7.5 / 30/60 Hz (depending on the model) in based on thermal camera resolution Linear signal / DDE, GigE Vision and GenICam compatible
Ethernet, alimentazione Supply Power over Ethernet, PoE IEEE 802.3af class 0
Ethernet, protocolli TCP, UDP, ICMP, IGMP, DHCP, GigEVision

Digital input / output

Digital input multi-purpose, 1 optically isolated, “0” <2, “1” = 2-12 V DC
Digital output, use Multi-use output for external device (set by program)
Digital output 1 optically isolated, 2-40 VDC, max 185 mA
I/O digital, isolation voltage 500 VRMS
I/O digital, power supply voltage 2–40 V CC, max 200 mA
I/O digital, type of connector 12-pin M12 connector (shared with digital synchronization and external power supply)
Synchronization In, use Frame synchronism input for camera control
Synchronism input 1, non-isolated
Synchronism input, type Buffer LVC a 3,3 V, “0” <0,8 V, “1”>2,0 V
Out synchronization, use Frame sync output for control of another Ax5 camera
Synchronism output 1, non-isolated
Synchronism output, type Buffer LVC a 3,3 V, ”0”=24 mA max, “1”= –24 mA max.
Digital synchronization, connector type 12-pin M12 connector (shared with digital I / O and external power supply)

Power supply system

external power supply 12/24 V DC, <3.5 W nominal <6.0 W absolute maximum
External power supply, connector type 12-pin M12 connector (shared with digital I / O and digital sync)
Voltage  Allowed range 10–30 V CC

Environmental specifications

Operating temperature range Da -15 °C a 60 °C
Storage temperature range Da -40 °C a 70 °C
Humidity (operation and storage) IEC 60068-2-30 / 24 h 95% relative humidity between 25 ° C and 40 ° C
EMC EN 61000-6-2 (Immunity) EN 61000-6-3 (Emissions) FCC 47 CFR Part 15 Class B (Emissions)
Protection IP 40 (IEC 60529)
Shocks 25 g (IEC 60068-2-27)
Vibrations 2 g (IEC 60068-2-6 e MIL-STD810G)

Physical specifications

Weight 0,21 kg
Thermal camera dimensions (L × P × A) 106 × 47 × 50 mm
Tripod mounting UNC ¼”-20 (su tre lati)
Base mounting 4 threaded mounting holes M3 (on the bottom)
Housing material Magnesium and alluminium
Supply
Packaging, contents rCardboard box, camera with lens, focus adjustment tool, paper documentation, user documentation on CD, FLIR Tools Flir A35 download fo

 